Showing 37–46 of 46 results

High pressure static analytic apparatus (VLE, VLLE, or gas solubility)

The measurement of phase equilibrium data (vapor-liquid equilibrium, gas solubility, etc.) may require high pressures and high temperatures. The cell can be manufactured in titanium or hastelloy C-276. This unit was manufactured by TOP INDUSTRIE to study the solubility of acid gases in aqueous alkanolamine solutions. The effects of various sulfur compounds on solubility can be explored through experiments using this equipment. The main body is equipped with two sapphire windows allowing a view inside the cell. This equipment can be used up to temperatures of 400 °C and pressures of 400 bar, The equilibrium cell is thermoregulated in a thermostatic chamber and can be charged with known amounts of substances. In the case of purified and degassed liquids or liquefied gases, this can be done with the aid of a piston injector pump (PMHP) which allows precise recording of volume differences.

Hydrothermal Synthesis Reactor HP/HT°

This range of autoclaves with metal/metal seal has been designed for high pressure and high temperature use, especially in petrology, volcanology and geology. It allows to study the behavior of rocks, the interactions between the material and its gas/liquid environment in extreme conditions. The samples are either placed directly in the compression fluid or placed in sealed gold capsules. The pressure is generated either by an aqueous medium using Henri's curves (P.V.T); or by pressurizing the sample directly into gas using a booster (up to 3500bar) or a gas multiplier (up to 7000bar).

LAMBDA Thermal Conductivity Meter

LAMBDA is a compact, operator-friendly transient hot wire instrument that facilitates a fast determination of the thermal conductivity, thermal diffusivity and specific heat capacity in a wide temperature and pressure range by means of the transient hot wire (THW) method, according to ASTM D7896-19. This highly accurate athermal calorimeter is suited for fluid analysis in the laboratory as well as in the field, including the measurement of thermal conductivity of nanoparticle dispersions/nano fluids. Our LAMBDA Thermal Conductivity Meter can be operated either in stand-alone mode or with the intuitive software (incl.) on your WINDOWS computer via RS-232/USB. highly accurate thermal conductivity meter for laboratory use wide measuring range (10 - 2000 mW/(m*K)) wide temperature range (-50°C to 300°C) fast, instationary resistance measurement by means of the hot wire method conforms to ASTM D7896-19 robust stainless steel sensor no unwanted influence of convection suitable for any type of fluid, powder or gel requires only small sample volumes (approx. 40 ml) high accuracy and repeatability (+/- 1 %) thermal conductivity (λ), thermal diffusivity (aT), specific heat capacity (cp) and temperature are displayed

QVis 01/o Process Viscometer

Our QVis 01/o inline viscosimeter automates your viscosity monitoring and generates measuring results that are reproducible and documentable. Banish flow cups and  keep track of your fluid viscosity at all times!

Application

Since measurement of the dynamic viscosity with QVis is completely independent of the direction of flow, the mounting of the QVis 01/o sensor can be realized in any form of pipe, regardless of the flow conditions in it. QVis can be operated in stand-alone mode or it can be connected to your PC: a comfortable Windows software is included in the delivery to allow you to automate measuring procedures and to further process the obtained data.  

Composition

The QVis 01/o inline viscometer consists of only two components: a probe and a compact electronic unit which are connected with a flexible cable. The robust plastic housing includes an electronic control and evaluation system and can be mounted on the nearest wall or installed in your control cabinet. The probe contains the unique SiO2 torsional tranducer and is equipped with a G 1″ screw connection to give you maximum flexibility in regard to the installation. Depending on your requirements further types of sensors (e.g. clamping-fastened sensors with a screw-cap or sensors with special thread or even flange connection) are available upon request.

ROCKING CELL RC5

With the Rocking Cell RC5 by PSL Systemtechnik hydrate-formation can be examined and effectiveness and efficiency of kinetic hydrate inhibitorsand the influence of corrosion inhibitorscan be tested in laboratory.

SAPPHIRE ROCKING CELL

Test of AA and KHI at deepwater conditions Multi-phase flow testing Full view polished test cell for optimization of inhibitors Ball run time measurement 4 designs - 2,6,8,20 test cells max Stringent test conditions for improvement on product safety for deepwater application Sour gas testing

TURBULENCE RHEOMETER – A FRICTION FLOW LOOP

The Turbulence Rheometer (TR), also known as Friction Flow Loop, is a fully automated laboratory instrument for analysis of flow behavior in pipelines. The TR is used to analyze all kinds of flow improver e.g. Drag Reducers (DRA), Friction Reducers or Viscosity Reducers.

WAX FLOW LOOP

Analysis of wax appearance and deposition in pipelines: The fully automated Wax Flow Loop by PSL Systemtechnik is a compact laboratory instrument to research deposition effects of waxes, paraffins and asphaltenes in pipelines.